Alarm Pre-Notice L10n Specification
Purpose
Define the required behavior for the pre-notice notification text when an alarm is approaching. The notification MUST display computed remaining minutes in the device locale rather than hardcoded Spanish text.
Requirements
Requirement: Computed Remaining Minutes
The system MUST compute the number of minutes remaining until alarm fire time at the
moment the pre-notice BroadcastReceiver fires and MUST use that value as the
displayed countdown, NOT a hardcoded string.
Remaining minutes MUST be floored (integer division). If the computed value is less than 1 minute, the system MUST clamp to 1 and display "1 min".
Scenario: Normal pre-notice (alarm is ~30 min away)
- GIVEN an alarm is scheduled 30 minutes in the future
- WHEN the pre-notice
BroadcastReceiverfires attriggerAtMillis - PRE_NOTICE_MILLIS - THEN the notification body displays the remaining minutes derived from
(triggerAtMillis - currentTimeMillis) / 60_000 - AND the displayed value is a positive integer (e.g. "30 min")
Scenario: Alarm scheduled with less than 30 min remaining
- GIVEN an alarm is scheduled with fewer than 30 minutes from now
- WHEN the pre-notice fires immediately (or is already past)
- THEN the computed remaining minutes MAY be 0 or negative
- AND the system clamps the displayed value to a minimum of 1 minute
Scenario: System clock drift
- GIVEN the device clock drifts so
currentTimeMillisexceedstriggerAtMillis - WHEN the receiver fires and computes remaining minutes
- THEN the system clamps to 1 and displays "1 min"
- AND does NOT display a negative number or crash
Requirement: L10n-Ready Notification Text
The system MUST NOT hardcode any natural-language string in the notification content.
The pre-notice message MUST be produced via a localized string resource that accepts
a {minutes} placeholder.
A new ARB key preNoticeCountdown MUST be added to all 13 locale ARB files. The
string template MUST follow the same pattern as the existing durationMinutesOnly
key.
Scenario: Device locale is Spanish
- GIVEN the device locale is
es - WHEN the pre-notice notification is posted
- THEN the notification body uses the Spanish translation of
preNoticeCountdownwith the computed minutes substituted
Scenario: Device locale is English
- GIVEN the device locale is
en - WHEN the pre-notice notification is posted
- THEN the notification body uses the English translation of
preNoticeCountdownwith the computed minutes substituted
Scenario: Missing locale translation (fallback)
- GIVEN the device locale has no translation for
preNoticeCountdown - WHEN the pre-notice notification is posted
- THEN the system falls back to the default locale translation (English)
- AND does NOT display an untranslated key name or crash
Requirement: Notification ID Stability
The pre-notice notification MUST be posted with the same stable notification ID
derived from alarmId that the system currently uses (notificationIdForAlarm(alarmId)).
Scenario: Pre-notice posted
- GIVEN an alarm with
alarmId = X - WHEN the pre-notice fires
- THEN
NotificationManagerCompat.notify()is called with IDnotificationIdForAlarm(X) - AND calling
notify()again with the same ID updates the existing notification rather than creating a duplicate
Requirement: No Additional Infrastructure
The pre-notice notification MUST be a single, static notification posted once at fire time. The system MUST NOT schedule per-minute update chains (AlarmManager repeat), WorkManager periodic tasks, or new foreground services to update the countdown text after posting.
Scenario: Notification posted
- GIVEN the pre-notice fires
- WHEN the notification is posted
- THEN exactly one
notify()call is made - AND no new AlarmManager intents, WorkManager jobs, or foreground services are started